Moisture in Nitrogen

15-09-2026

Why a dry nitrogen reading at the generator is not enough

If you operate modified atmosphere packaging, you are likely to already monitor nitrogen or CO₂ purity.

However, purity and dryness are not the same thing.

A dry nitrogen reading at one point in the system does not guarantee that the gas remains dry everywhere else.

A gas can also show the correct oxygen or carbon dioxide percentage while still containing too much moisture.

That excess moisture can create problems inside the pack.

For example, above a water activity of around 0.85, mould can begin to establish itself in a product that appeared perfectly acceptable when it was sealed.

In powders, moisture can cause particles to bridge together and form lumps, potentially leading to blockages in dispensing systems.

In snacks and baked products, moisture can soften the structure that gives the product its crisp texture.

This can happen well before the best before date.

None of these problems necessarily appear on the production line.

Instead, they may only become visible later through a customer complaint, returned pallet or failed shelf life trial.

By that stage, the gas may have been causing problems for weeks.

Many plants check gas dryness once at the generator and consider the job complete.

It is an understandable approach because this is where the gas is produced and it is often the easiest point to instrument.

However, a single dry nitrogen reading only confirms that the gas was dry at that moment and at that particular location.

It does not show what happens to the gas afterwards.

Where the gas actually picks up moisture

The section between the generator and the point of use is where problems can begin.

In practice, this can happen in several specific ways.

A quick-connect coupling on a hose line can allow ambient air back into the system.

A hose left open between production runs can have the same effect.

Opening a gas manifold during a changeover creates a similar risk on a smaller scale.

Because this can happen on every line and during every changeover, it becomes a routine risk rather than an occasional one.

The second cause is less obvious because nothing needs to be opened.

A distribution pipe may pass through a colder part of the plant, such as near a loading bay, external wall or unheated ceiling void.

In these areas, the pipe wall itself can approach the gas’s pressure dewpoint.

When that happens, water can condense out of the gas and collect inside the pipe, even though the header reading upstream remains comfortably dry.

The gas may therefore have been genuinely dry when it left the buffer receiver, but it did not remain that way.

Both failure modes can produce the same result.

The generator or header monitor shows an acceptable reading, while the gas reaching the package is wetter than it should be.

Why this matters beyond the packaging line

This is not only a packaging line issue.

Wet feed air can also degrade the carbon molecular sieve in a PSA generator over time.

As a result, a moisture problem can eventually affect the generator itself.

This may then reduce the purity and dryness of the gas it produces.

There is also an audit consideration.

Many GFSI-benchmarked audit schemes ask for dewpoint monitoring at the distribution header.

A plant checking only at the generator may therefore show a compliant reading that does not necessarily reflect the condition of the gas reaching the product.

For plant engineering and QA teams, this is the main concern.

A monitoring arrangement based around a single point can appear satisfactory while still allowing moisture-related spoilage to occur.

The reason is simple: the monitored point and the point of failure may not be in the same place.

Applicable standards

ISO 8573-1:2010 covers compressed air contaminants and purity classes, including water and dewpoint classes.

Class 2 specifies a pressure dewpoint of -40 °C or better for direct food contact, while Class 4 specifies +3 °C for indirect contact.

EIGA Doc 126/20 provides minimum specifications for food gas applications, including nitrogen (E941) and carbon dioxide (E290), and includes moisture limits.

SQF Guidance, April 2023 includes the Air and Other Gases Guidance Document, referenced by GFSI-benchmarked audit schemes, covering monitoring of compressed air and process gases in food production, including moisture testing considerations.

Our application note explains where dewpoint should be measured across a food packaging gas system.

It follows the process from the dryer outlet and generator feed, through the distribution header, to the flow-wrap or FFS manifold.

It also explains which standards apply at each stage, including ISO 8573-1:2010, EIGA Doc 126/20 and SQF’s Air and Other Gases guidance.

Visit the Shaw Moisture Meters (UK) Ltd website for more information on Moisture in Nitrogen